1. Exquisite low temperature technology
High quality oxygen free copper pipe, nitrogen filled welding, high pressure maintaining and leak proof technology are used to ensure the welding quality of the low temperature connecting pipe in the walk-in constant temperature and humidity laboratory. The length, inclination, gradient and trend of the pipe must be strictly calculated to achieve the best refrigeration effect;
2. Main refrigeration accessories
1) Refrigeration compressor: the original imported low-noise scroll cascade mechanical refrigeration system is adopted. This type of compressor should be able to achieve large refrigeration capacity, low noise, low energy consumption and high efficiency. The equipment adopts (Taikang brand fully enclosed type) or German gurun brand semi enclosed type refrigeration compressor unit, and it shall be able to ensure long-term, stable and reliable operation.
2) . refrigeration evaporator: the fin evaporator is 30% higher than the general evaporator in heat exchange efficiency, with the advantages of beauty, small size, fast cooling, etc.
3) , oil separator and refrigeration oil
Whether the refrigeration compressor has enough and reasonable high-quality refrigeration oil will directly affect its service life. If the refrigeration oil enters the refrigeration system, especially the heat exchanger, its performance will be greatly reduced. Therefore, the oil separator should be set in the system, and the imported oil separator and refrigerator with the best performance should be used, with the most stable oil performance and viscosity.
3. Due to the low humidity, install the dehumidification system!
4) High efficiency condensing evaporator
At present, the world's advanced brazed plate heat exchanger is used. This kind of heat exchanger is composed of several corrosion-resistant stainless steel sheets which are used to suppress the herringbone shaped ripples. The adjacent stainless steel sheets have opposite corrugations, and the corrugations back lines intersect each other to form a large number of contact solder joints. Because of the complex contact network channel, the fluid on both sides forms turbulence, which improves the heat exchange intensity and is strong at the same time The turbulent flow and smooth stainless steel surface make the inner surface of the heat exchange channel of the brazed plate not easy to scale. After using this heat exchanger, not only the system resistance is reduced, but also the disadvantages of large size, poor heat exchange and low efficiency of this part in the previous large-scale domestic low-temperature test chamber can be overcome.
3. Main refrigeration accessories: solenoid valve (Japan Heron Palace), manual stop valve (imported Danfoss), filter (imported Danfoss), expansion valve (imported Danfoss), pressure controller (imported Danfoss), vibration proof hose (US Paris), muffler (US Aigo), electronic expansion valve (imported Danfoss), etc. are all imported famous equipment;
4. Refrigerant: R404A, R23, R22 meet the requirements of international environmental protection convention.
|